Range Hood CFM & Duct Sizing

The first question is not how many CFM the hood has. It is what the cooktop produces and how far the hood can capture it. A 36 inch gas range with a high-output burner needs more ventilation than a 30 inch induction cooktop. The hood should be wider than the cooking surface, mounted at the manufacturer's recommended height, and connected to a duct that can carry the airflow.

At a glance

Planning cost
$900–$3,800
Timeline
3 days
Heat / moisture
8/10
Slip / stain
8/10
Maintenance
Moderate

Start with capture area

A hood should extend beyond the cooktop on both sides and, in many installations, 3 to 6 inches beyond the front. A hood that is the same width as the cooktop will lose smoke at the edges. A deeper hood or a lower mounting height improves capture, but it can block the cook's view.

The mounting height depends on the cooktop and the hood. A wall hood is often 24 to 30 inches above the cooking surface; an island hood may be 30 to 36 inches. Follow the manufacturer's clearance and the local code. A hood mounted too high will lose capture even if the CFM is high.

Hood width and mounting height
Cooktop widthHood widthTypical mounting height
30 in36 in24 to 30 in above the cooktop
36 in42 to 48 in24 to 30 in above the cooktop
48 in54 to 60 in30 to 36 in above the cooktop

Calculate the CFM

A common starting rule for gas cooking is 100 CFM per 10,000 BTU. A 60,000 BTU range would need 600 CFM. For electric and induction cooking, a common rule is 100 CFM per 10 inches of cooktop width, so a 30 inch cooktop needs 300 CFM and a 36 inch cooktop needs 360 CFM.

Add capacity for high-heat cooking, a long duct run, or a hood with a restrictive baffle filter. A 36 inch pro-style gas range with a 15,000 BTU burner may need 900 to 1,200 CFM. A 30 inch induction cooktop may be fine with 300 to 400 CFM if the duct is short and the hood captures well.

Starting CFM targets
Cooking surfaceStarting CFMHigh-heat or long duct
30 in electric or induction300 CFM400 to 500 CFM
36 in electric or induction360 CFM500 to 600 CFM
30 in gas, 40,000 BTU400 CFM500 to 600 CFM
36 in gas, 60,000 BTU600 CFM800 to 1,000 CFM
48 in pro range, 80,000+ BTU800 to 1,000 CFM1,200+ CFM

Size the duct for velocity

Duct velocity should usually be 1,000 to 1,500 feet per minute for a kitchen exhaust. A 6 inch duct can carry about 300 to 600 CFM at that velocity; a 7 inch duct can carry about 600 to 900 CFM; an 8 inch duct can carry about 900 to 1,200 CFM. A 4 inch duct is too small for almost any kitchen hood.

Every elbow, transition, and roof cap adds resistance. A 90-degree elbow can be equivalent to 5 to 10 feet of straight duct, depending on the radius. A short, straight run with two 45-degree elbows is much better than a long run with three 90-degree turns.

Duct sizing rules of thumb
Duct sizeComfortable CFMNotes
4 inUp to 200 CFMToo small for most kitchen hoods
6 in300 to 600 CFMShort, straight run
7 in600 to 900 CFMBetter for a pro-style hood
8 in900 to 1,200 CFMLarge hood or long run
10 in1,200+ CFMHigh-output or remote blower

Equivalent length and makeup air

Add the equivalent length of every fitting to the straight duct length. A typical limit is 30 to 50 equivalent feet for a residential hood, but the manufacturer's table is the authority. If the run exceeds the limit, increase the duct size or choose a remote blower.

A powerful hood needs replacement air. In a tight house, a 600 CFM hood can depressurize the kitchen and pull air back through a water heater flue. A makeup-air system or a controlled intake may be required. Do not assume an open window is enough.

The installation sequence.

  1. Record the cooktop width, fuel type, and total BTU or wattage.
  2. Choose a hood that is wider than the cooktop.
  3. Calculate a starting CFM and add a margin for high-heat cooking.
  4. Map the duct route and count every elbow and transition.
  5. Select a duct size that keeps velocity in the 1,000 to 1,500 fpm range.
  6. Check the equivalent length against the manufacturer's limit.
  7. Plan makeup air and commission the system with a smoke test.

What to remember.

  • Capture area and mounting height matter as much as CFM.
  • A 6 inch duct is not enough for a high-output hood.
  • Every elbow adds resistance; keep the run short and straight.
  • A tight house may need makeup air for a powerful hood.

Field note

If the hood is on an island, choose a larger capture area and a lower mounting height before you increase the CFM. More airflow cannot fix a hood that is too small or too high.

The schedule

Guide profile in one table.

The same fields used across the benchmark set, so this guide can be compared with the styles, layouts, and materials it references.

Profile for the Range Hood CFM & Duct Sizing guide, including topic, read time, sections, steps, tables, cost, timeline, ratings, and room-size fit.
FieldValue
TopicVentilation
Read time4 minutes
Sections4
Steps7
Data tables3
Planning cost$900–$3,800
Install timeline3 days
Heat / moisture8/10
Slip / stain8/10
MaintenanceModerate
Ideal room80 sq ft–500 sq ft
Task light3000K

Apply the guide

Where this rule meets a plan.

The guide is only useful when it meets a measured layout. These combinations apply the same dimensions to a specific style and material schedule.

Open the matrix

Modern Minimalist / Galley kitchen

001

Galley Double-Run Kitchen

Size
9 × 14 ft
Budget
$49,000–$130,000
Build
41–78 d
Porcelain Large-Format SlabMatte Fenix Laminate CabinetsUnlacquered Brass Faucet
Open the plan

Shaker Transitional / Galley kitchen

003

Galley Double-Run Kitchen

Size
9 × 14 ft
Budget
$57,150–$150,550
Build
44–83 d
Porcelain Large-Format SlabPull-Out Pantry LarderUnder-Cabinet LED Task Strip
Open the plan

The trade-offs

What the guide assumes.

Every rule has a boundary. These are the conditions behind this one.

What works

  • A correctly sized hood removes moisture, grease, and odors.
  • A short, straight duct reduces noise and improves airflow.
  • A wider hood captures more smoke at the edges.

What to watch

  • A high-CFM hood can require makeup air and a larger duct.
  • A downdraft captures less smoke than an overhead hood.
  • A long duct run can make a good hood perform poorly.

Read next

Related field guides.

The next question is usually one section over.

All guides

Kitchen planning / 5 min

G01

Work Triangle Leg Dimensions

A measured guide to the sink-cook-fridge triangle, including leg lengths, total travel, obstruction rules, and plan-specific exceptions.

5 sectionsRead →

Clearances / 4 min

G02

Kitchen Aisle Clearance Standards

A practical guide to kitchen aisle widths, appliance door clearances, seating clearance, and the difference between a code minimum and a comfortable work zone.

4 sectionsRead →

Countertops / 4 min

G03

Countertop Hardness, Stain & Heat

A material-by-material guide to Mohs hardness, heat resistance, stain and etch risk, edge durability, and sealing for kitchen counters.

4 sectionsRead →

FAQ

Ventilation questions.

Practical answers drawn from the specification, cost model, and installation sequence.

How many CFM do I need for a 36 inch gas cooktop?
A 36 inch gas cooktop with 60,000 BTU total needs about 600 CFM as a starting point. Add capacity for high-heat burners, a long duct, or a restrictive baffle. A pro-style range may need 900 to 1,200 CFM.
Can I use a 4 inch duct for a range hood?
A 4 inch duct is too small for most kitchen hoods. It can only carry about 200 CFM at a reasonable velocity. Use a 6 inch duct for 300 to 600 CFM and a larger duct for a high-output hood.
Do I need makeup air for a 600 CFM hood?
It depends on the house tightness and the other combustion appliances. A 600 CFM hood can depressurize a tight house. A blower-door test and a makeup-air calculation are the right way to decide. Do not rely on an open window as a permanent solution.