A measured index of the American kitchen

Kitchen Room Index
Menu
Ventilation4 min read5 sections7 steps

Kitchen Ventilation & Makeup Air

The need for makeup air depends on the hood CFM, the house tightness, and the combustion appliances. A 300 CFM hood in a leaky house may be fine. A 900 CFM hood in a new tight house may need a dedicated makeup-air system. The right answer comes from a blower-door test and a load calculation, not a rule of thumb.

At a glance

Planning cost
$800–$6,000
Timeline
3 days
Heat / moisture
8/10
Slip / stain
8/10
Maintenance
Moderate

Why makeup air matters

A hood is an exhaust fan. It moves air out of the kitchen, and that air has to be replaced. In a leaky house, the replacement air comes through gaps around windows and doors. In a tight house, it may come from a crawlspace, an attic, or a water heater flue.

Backdrafting is the dangerous version. A negative pressure can pull combustion gases from a gas water heater or furnace into the house. A carbon monoxide alarm is not a substitute for a proper pressure test and a makeup-air plan.

Pressure and exhaust
Hood CFMHouse tightnessMakeup air
300LeakyUsually not required
300TightTest; a small intake may be enough
600TightLikely required
900+AnyPlan a system; test the pressure

Signs of a pressure problem

A door that is hard to open when the hood is running is a sign of negative pressure. A water heater flue that spills or a fireplace that smokes is a serious sign. A hood that seems weak despite a high CFM may be starved for air.

Do not ignore a smell of exhaust gas or a CO alarm. Turn off the hood, open a window, and call a qualified technician. A pressure problem is a safety issue, not a comfort issue.

  • The hood is noisy but does not capture smoke.
  • A door is hard to open when the hood runs.
  • The water heater flue spills or the fireplace smokes.
  • A CO alarm sounds when the hood is on.

Sizing the makeup air

A makeup-air system should provide enough air to balance the hood without over-pressurizing the house. The exact size depends on the hood CFM, the house volume, the tightness, and the combustion appliances. An engineer or a qualified HVAC contractor should calculate it.

A common approach is to provide makeup air at 80 to 100 percent of the exhaust CFM, tempered and filtered. A smaller intake can work if the house is leaky, but it should be tested. A motorized damper interlocked with the hood prevents backdrafts when the hood is off.

Makeup-air components
ComponentPurposeNote
Intake hoodWeather protectionInsect screen and filter
Motorized damperOpens with the hoodInterlocked, not manual
DuctCarries the airSize for low velocity
FilterCleans the airAccessible for service
HeaterTempered airRequired in a cold climate
ControllerBalances the systemPressure or CFM based

Strategies that work

A dedicated makeup-air unit with a motorized damper, a filter, and a tempering heater is the most reliable solution. A simpler approach is a passive intake with a barometric damper, but it can be drafty and hard to balance. A heat-recovery ventilator can provide fresh air, but it is not sized for a 900 CFM hood.

Do not use a window as the permanent makeup air source. It is uncontrolled, unfiltered, and a security issue. A window can be a temporary test, not a design.

Commissioning and maintenance

Commission the system with a pressure test and a smoke test. Run the hood at high speed and check the pressure in the kitchen and the mechanical room. Confirm the damper opens and closes, the heater works, and the filter is accessible.

Change the filter on schedule and check the damper every year. A stuck damper can turn a good system into a backdraft risk. Keep the commissioning report with the project file.

The installation sequence.

  1. Record the hood CFM and the appliance fuel types.
  2. Perform a blower-door test or a pressure test.
  3. Check the combustion appliances for backdraft risk.
  4. Calculate the makeup-air requirement with a qualified contractor.
  5. Choose an interlocked, filtered, tempered system.
  6. Commission with a pressure test and a smoke test.
  7. Maintain the filter and the damper annually.

What to remember.

  • A hood removes air; the house needs a path for replacement air.
  • A tight house can need makeup air at 600 CFM or less.
  • A motorized damper interlocked with the hood prevents backdrafts.
  • A CO alarm is not a substitute for a pressure test.

Field note

Test the pressure with the hood on high and the clothes dryer running. The worst case is the one that matters, not the best-case test.

The schedule

Guide profile in one table.

The same fields used across the benchmark set, so this guide can be compared with the styles, layouts, and materials it references.

Profile for the Kitchen Ventilation & Makeup Air guide, including topic, read time, sections, steps, tables, cost, timeline, ratings, and room-size fit.
FieldValue
TopicVentilation
Read time4 minutes
Sections5
Steps7
Data tables2
Planning cost$800–$6,000
Install timeline3 days
Heat / moisture8/10
Slip / stain8/10
MaintenanceModerate
Ideal room80 sq ft–500 sq ft
Task light3000K

Apply the guide

Where this rule meets a plan.

The guide is only useful when it meets a measured layout. These combinations apply the same dimensions to a specific style and material schedule.

Open the matrix

Modern Minimalist / Galley kitchen

003

Galley Double-Run Kitchen

Size
9 × 14 ft
Budget
$49,000–$130,000
Build
41–78 d
Porcelain Large-Format SlabMatte Fenix Laminate CabinetsUnlacquered Brass Faucet
Open the plan

The trade-offs

What the guide assumes.

Every rule has a boundary. These are the conditions behind this one.

What works

  • Makeup air keeps a powerful hood from depressurizing the house.
  • A motorized damper prevents backdrafts when the hood is off.
  • A filtered intake keeps dust and pollen out of the kitchen.

What to watch

  • A tempered makeup-air system adds cost and space.
  • A passive intake can be drafty and hard to balance.
  • The system needs annual maintenance.

Read next

Related field guides.

The next question is usually one section over.

All guides

Kitchen planning / 5 min

G01

Work Triangle Leg Dimensions

A measured guide to the sink-cook-fridge triangle, including leg lengths, total travel, obstruction rules, and plan-specific exceptions.

5 sectionsRead →

Clearances / 4 min

G02

Kitchen Aisle Clearance Standards

A practical guide to kitchen aisle widths, appliance door clearances, seating clearance, and the difference between a code minimum and a comfortable work zone.

4 sectionsRead →

Ventilation / 4 min

G03

Range Hood CFM & Duct Sizing

A technical guide to hood sizing, capture area, duct velocity, equivalent length, and the ventilation details that make a kitchen work.

4 sectionsRead →

FAQ

Ventilation questions.

Practical answers drawn from the specification, cost model, and installation sequence.

Do I need makeup air for a 600 CFM hood?
It depends on the house tightness and the combustion appliances. A 600 CFM hood can depressurize a tight house. A blower-door test and a pressure test are the right way to decide. Do not assume an open window is enough.
What happens if a kitchen has no makeup air?
The house can depressurize, which may cause backdrafting from a water heater or fireplace, draw dust from an attic, or make doors hard to open. In a severe case, combustion gases can enter the house.
Can a heat-recovery ventilator provide makeup air?
An HRV provides fresh air and recovers heat, but it is usually sized for whole-house ventilation, not a 900 CFM hood. A dedicated makeup-air unit is the right choice for a high-CFM hood.